SIMM/DIMM/RIMM memory errors

The following SIMM/DIMM/RIMM error messages are issued by the diagnostic

programs.

Error FRU/Action
2xx-1y
Amemory error was detected in SIMM
socket Y.
Replace the SIMM in the socket identified by
the last digit of the error code.
Re-run the test.
If the same error code occurs again, replace
the system board.
2xx-2y
Amemory error was detected in
DIMM/RIMM socket Y
Replace the DIMM/RIMM in the socket
identified by the last digit of the error code.
Re-run the test.
If the same error code occurs again, replace
the system board or where memory is on
the processor card, replacethe processor
card.
Corrupt BIOS
Information in BIOS is not as expected.
Not able to find expected DMI information
from BIOS.
Memory controller chipset vendor ID does
not match expected value.
Reflash the BIOS.
Perform boot block recovery.
Replace the system board.
Testaborted by user Restart test.

Note: Yis the SIMM/DIMM/RIMM socket number. Use the System BoardLayout

section in the latest Hardware Maintenance Manual (HMM) to reference the

memory sockets.