Diagnostic Error Code FRU/Action
015-002-XXX
USB port Timeout 1. Remove USB device(s) and re-test
2. System board
015-015-XXX
USB port External Loopback failure 1. Remove USB device(s) and re-test
2. System board
015-027-XXX
USB port Configuration/Setup error 1. Flash the system
2. System board
015-032-XXX
USB port Device Controller failure 1. System board
015-034-XXX
USB port buffer
allocation failure
1. Reboot the system
2. Flash the system
3. Run memory test
4. System board
015-035-XXX
USB port Reset condition detected 1. Remove USB device(s) and re-test
2. System board
015-036-XXX
USB port Register error 1. Systemboard
015-040-XXX
USB port IRQ failure 1. Run setup and check for conflicts
2. Flash the system
3. System board
015-195-XXX
USB port Testaborted by user 1. Information
2. Re-start the test, if necessary
015-196-XXX
USB port test halt, error threshold exceeded 1. Press F3 to review the log file
2. Re-start the test to reset the log file
015-197-XXX
USB port test warning 1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
015-198-XXX
USB port test aborted 1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problems
section
015-199-XXX
USB port test failed, cause unknown 1. Goto the Undetermined problems
section
2. Flash the system and re-test
3. Replace component under function test
018-000-XXX
PCI Card TestPassed 1. No action
018-0XX-XXX
PCI Card Failure 1. Riser card, if installed
2. System board
50 HardwareMaintenance Manual