POST Error Code FRU/Action
180X, 188X
PCI configuration or resource error 1. Run Setup and verify PCI/ISA
configuration settings.
2. If necessary,set ISA adapters to Not
available to allow PCI adapters to
properly configure.
3. Remove any suspect ISAadapters.
4. Rerun diagnostics.
5. PCI Adapter
1962
Boot sequence error 1. Possible hard disk drive problem; see
“Hard disk drive boot error”on page
41.
209X 1. Diskette Drive
2. Diskette Cable
20XX
Not listed above 1. BSC Adapter
21XX 1. SCSI Device
2. 16-bit ATFast SCSU adapter
3. Alternate BSC adapter
2401, 2402
If screen colors change 1. Display
2401, 2402
If screen colors are OK 1. SystemBoard
2. Display
2409 1. Display
2410 1. System Board
2. Display
2462
Videomemory configuration error 1. Check cable connections
2. Run Setup and verify video
configuration settings
3. VideoMemory Modules
4. VideoAdapter (if installed)
5. System Board
4611, 4630 1. Multiport/2 Interface Board
2. Multiport/2 Adapter
4612, 4613, 4640, 4641 1. Memory Module Package
2. Multiport/2 Adapter
4650 1. Multiport/2 Interface Cable
46XX
Not listed above 1. Multiport/2 Adapter
2. Multiport/2 Interface
Board
3. Memory Module
5600 1. Financial System Controller Adapter
Chapter6. Symptom-to-FRU Index 69