Diagnostic Error Code FRU/Action
001-038-XXX
System Extension failure 1. Adapter card
2. System board
001-039-XXX
System DMI data structure error 1. Flash the system
2. System board
001-040-XXX
System IRQ failure 1. Power-off/on system and re-test
2. System board
001-041-XXX
System DMA failure 1. Power-off/on system and re-test
2. System board
001-195-XXX
System Testaborted by user 1. Information
2. Re-start the test, if necessary
001-196-XXX
System test halt, error threshold exceeded 1. Press F3 to review the log file
2. Re-start the test to reset the log file
001-197-XXX
System test warning 1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
001-198-XXX
System test aborted 1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test
3. Go to the ″Undetermined problems″
section
001-199-XXX
System test failed, cause unknown 1. Go to the ″Undetermined problems″
section
2. Flash the system and re-test
3. Replace component under function test
001-250-XXX
System ECC error 1. System board
001-254-XXX
001-255-XXX
001-256-XXX
001-257-XXX
System DMA error
1. System board
001-260-XXX
001-264-XXX
System IRQ error
1. System board
001-268-XXX
System IRQ1 failure 1. Device on IRQ1
2. System board
001-269-XXX
System IRQ2 failure 1. Device on IRQ2
2. System board
001-270-XXX
System IRQ3 failure 1. Device on IRQ3
2. System board
44 HardwareMaintenance Manual