Diagnostic Error Code FRU/Action
175-199-XXX
Thermal Sensor(s) test failed, cause
unknown
1. Go to the Undetermined problems
section
2. Flash the system and re-test
3. Replace component under function test
175-250-XXX
175-251-XXX
Thermal Sensor(s) limit error
1. Check fans
2. Check Power supply
3. Microprocessor
4. System board
185-000-XXX
Asset Security TestPassed 1. No action
185-XXX-XXX
Asset Security failure 1. Flash system
2. System board
185-278-XXX
Asset Security Chassis Intrusion 1. Assure Asset Security Enabled
2. C2 Cover Switch
3. System board
201-000-XXX
System Memory TestPassed 1. No action
201-XXX-XXX
System Memory error 1. Replacethe memory module called out
by the test
2. System board
202-000-XXX
System Cache TestPassed 1. No action
202-XXX-XXX
System Cache error 1. Cache, if removable
2. System board
3. Microprocessor
206-000-XXX
Diskette Drive TestPassed 1. Noaction
206-XXX-XXX
Diskette Drive error 1. DisketteDrive Cable
2. Check power supply voltages
3. Diskette drive
4. System board
215-000-XXX
CD-ROM Drive TestPassed 1. No action
215-XXX-XXX
CD-ROM Drive error 1. CD-ROM Drive Cable
2. Check power supply voltages
3. CD-ROM drive
4. System board
217-000-XXX
Hard Disk Drive TestPassed 1. Noaction
217-25X-XXX
217-26X-XXX
Hard Disk Drive (IDE) error
1. Hard Disk Drive Cable
2. Check power supply voltages
3. Hard Disk drive (IDE)
4. System board
58 HardwareMaintenance Manual