Self-diagnosis Function

This monitor is equipped with a self-diagnosis function. If there is a problem with your monitor or computer, the screen will go blank and the u indicator will either light up green or flash orange.

u indicator

If the u indicator is green

1Disconnect the video input cable or turn off the connected computer.

2Press and hold the >/button for 2 seconds.

If all four color bars appear (white, red, green, blue), the monitor is working properly. Reconnect the video input cable and check the condition of your computer.

If the color bars do not appear, there is a potential monitor failure. Inform your service representative of the monitor’s condition.

If the u indicator is flashing orange

Press the u button to turn the monitor off and on.

If the u indicator lights up green, the monitor is working properly.

If the u indicator is still flashing, there is a potential monitor failure. Inform your service representative of the monitor’s condition. Be sure to note the model name and serial number of your monitor. Also note the make and model of your computer and video board.

 

Additional Information

 

 

Specifications

Picture tube

0.25 mm aperture grille pitch

 

17 inches measured diagonally

 

90-degree deflection

Viewable image size

Approx. 327 × 242 mm (w/h)

 

(12 7/8 × 9 5/8 inches)

 

16.0” viewing image

Resolution

Horizontal: Max. 1280 dots

 

Vertical: Max. 1024 lines

Standard image area

Approx. 312 × 234 mm (w/h)

 

(12 3/8 × 9 1/4 inches)

Deflection frequency

Horizontal: 30 to 85 kHz

 

Vertical: 50 to 150 Hz

 

256 < Total Line < 1700

AC input voltage/current

100 to 240 V, 50 – 60 Hz, 1.9 – 1.1 A

Power consumption

Max. 120 W

Dimensions

408 × 441 × 434 mm (w/h/d)

 

(16 1/8 × 17 3/8 × 17 1/8 inches)

Mass

Approx. 19.2 kg (41 lb 14 oz)

Design and specifications are subject to change without notice.