Symptom-to-FRU index

Symptom or error

FRU or action, in sequence

 

 

 

2000

1.

Undock docking station or port

Hard Drive Active Protection sensor

 

replicator if it is attached to the

diagnostics failed.

 

ThinkPad computer, and place the

Press <Esc> to continue.

 

computer on a horizontal surface. Do not

Press <F1> to enter SETUP

 

apply any physical shock to the

 

 

computer.

 

2.

Run Diagnostics -->ThinkPad Devices

 

 

-->HDD Active Protection Test.

 

 

2010

Inform the following information to the

Warning: Your internal hard disk drive

customer:

(HDD) may not function correctly on this

If in the primary bay the customer is using a

system. Ensure that your HDD is supported

non-IBM or non-Lenovo hard disk drive

on this system and that the latest HDD

(HDD), or an old generation IBM HDD

firmware is installed.

which is not supported by this system, with

 

the risk in mind, the customer can still use it

 

by pressing ESC. If in the primary drive bay

 

the customer is using a supported

 

IBM/Lenovo HDD with an old firmware,

 

the customer needs to update its firmware to

 

the latest. The latest version is available at

 

http://www.lenovo.com/support

 

 

 

2100

1.

Reseat the hard disk drive.

Initialization error on HDD0 (Main hard

2.

Main hard disk drive.

disk drive)

3.

System board.

 

 

 

2102

1.

Reseat the hard disk drive.

Initialization error on HDD1 (Ultrabay hard

2.

Ultrabay hard disk drive.

disk drive)

3.

System board.

 

 

 

2110

1.

Reseat the hard disk drive.

Read error on HDD0 (Main hard disk drive)

2.

Main hard disk drive.

 

3.

System board.

 

 

 

2112

1.

Reseat the hard disk drive.

Read error on HDD1 (Ultrabay hard disk

2.

Ultrabay hard disk drive.

drive)

3.

System board.

 

 

 

52MT 1951, 1952, 1953, 1954, 1955, 1956, 2007, 2008, 2009, 2613, 2623, and 2637

Page 58
Image 58
IBM T60P manual Symptom or error FRU or action, in sequence 2000, Run Diagnostics -- ThinkPad Devices, 2010