Symptom or error | FRU or action, in sequence | |
|
|
|
2000 | 1. | Undock docking station or port |
Hard Drive Active Protection sensor |
| replicator if it is attached to the |
diagnostics failed. |
| ThinkPad computer, and place the |
Press <Esc> to continue. |
| computer on a horizontal surface. Do not |
Press <F1> to enter SETUP |
| apply any physical shock to the |
|
| computer. |
| 2. | Run Diagnostics |
|
| |
|
| |
2010 | Inform the following information to the | |
Warning: Your internal hard disk drive | customer: | |
(HDD) may not function correctly on this | If in the primary bay the customer is using a | |
system. Ensure that your HDD is supported | ||
on this system and that the latest HDD | (HDD), or an old generation IBM HDD | |
firmware is installed. | which is not supported by this system, with | |
| the risk in mind, the customer can still use it | |
| by pressing ESC. If in the primary drive bay | |
| the customer is using a supported | |
| IBM/Lenovo HDD with an old firmware, | |
| the customer needs to update its firmware to | |
| the latest. The latest version is available at | |
| http://www.lenovo.com/support | |
|
|
|
2100 | 1. | Reseat the hard disk drive. |
Initialization error on HDD0 (Main hard | 2. | Main hard disk drive. |
disk drive) | 3. | System board. |
|
|
|
2102 | 1. | Reseat the hard disk drive. |
Initialization error on HDD1 (Ultrabay hard | 2. | Ultrabay hard disk drive. |
disk drive) | 3. | System board. |
|
|
|
2110 | 1. | Reseat the hard disk drive. |
Read error on HDD0 (Main hard disk drive) | 2. | Main hard disk drive. |
| 3. | System board. |
|
|
|
2112 | 1. | Reseat the hard disk drive. |
Read error on HDD1 (Ultrabay hard disk | 2. | Ultrabay hard disk drive. |
drive) | 3. | System board. |
|
|
|
52MT 1951, 1952, 1953, 1954, 1955, 1956, 2007, 2008, 2009, 2613, 2623, and 2637