Checkout guide

5

1(+) 2(+) 3 4

7(-) 6(-)

Terminal

Voltage (V dc)

 

 

1

+ 0 to + 12.6

 

 

7

Ground (−)

 

 

3.If the voltage is less than +11.0 V dc, the battery pack has been discharged.

Note: Recharging will take at least 3 hours, even if the indicator does not turn on.

If the voltage is still less than +11.0 V dc after recharging, replace the battery.

4.If the voltage is more than +11.0 V dc, measure the resistance between battery terminals 5 and 7. The resistance must be 4 to 30 K .

If the resistance is not correct, replace the battery pack. If the resistance is correct, replace the system board.

Checking the backup battery

Do the following:

1.Power off the computer, and unplug the ac adapter from it.

2.Turn the computer upside down.

3.Remove the battery pack (see “1010 Battery pack” on page 63).

4.Remove the backup battery (see “1110 Backup battery” on page 85).

5.Measure the voltage of the backup battery. See the following figure.

Red (+)

Black (-)

Wire

Voltage (V dc)

 

 

Red

+2.5 to +3.2

 

 

Black

Ground

 

 

vIf the voltage is correct, replace the system board.

vIf the voltage is not correct, replace the backup battery.

vIf the backup battery discharges quickly after replacement, replace the system board.

36MT 1951, 1952, 1953, 1954, 1955, 1956, 2007, 2008, 2009, 2613, 2623, and 2637

Page 42
Image 42
IBM T60P manual Checking the backup battery, Terminal Voltage V dc, Wire Voltage V dc