Indesit IT50E1 S Installation, Electrical connection, Warning - This Appliance Must Be Earthed

Models: IT50E1 S IT50E S

1 20
Download 20 pages 14.7 Kb
Page 5
Image 5
Installation

Installation

WARNING – THIS APPLIANCE MUST BE EARTHED .

Electrical connection

Electric cookers come without a power supply cable. The cooker is designed to operate on an electricity supply which conforms to the electrical data shown on the Rating Plate. The cooker can be connected to the mains only after removing the back panel of the cooker itself with a screwdriver.

!The following installation procedure must be carried out by a qualified electrician. The electrical installation must comply with the IEE Regulations, Building & local By-Lays.

For the installation of the feeding cable carry out the following operations:

1 Open the terminal board by inserting a screwdriver into the side tabs of the cover. Use the

screwdriver as a lever by pushing it down to open the cover (see diagram).

2 Loosen the cable clamp screw and remove it, using a screwdriver as a lever (see figure).

Positioning the Cooker

mm

150 mm

650

 

150 mm

 

Moving the Cooker

GB

The height of the cooker can be adjusted by means of adjustable feet in the plinth (900mm

-915mm). Adjust the feet by tilting the cooker from the side. Then install the product into position. NOTE: This appliance must not be fitted on a platform.

The cooker is designed to fit between kitchen cabinets spaced 500mm apart. The space either side need only be sufficient to allow withdrawal of the cooker for servicing. It can be used with cabinets one side or both as well as in a corner setting. It can also be used free-

3 Remove the wire

contact screws L-N-WARNING – THIS APPLIANCE MUST BE EARTHED ., then fasten the wires

under the screw heads, respecting

the colour code: Black/Blue (N), Red/Brown

(L) and Bare Wire/Yellow-Green (Electrical connection).

Once the connections have been made, tighten all

the terminal screws fully.

Fasten the supply cable in place with the clamp and close the cover of the terminal board.

N.B.: the power supply cable must have these minimum requirements:

Type: H05RR-F H05VV-FSection: 3x4 mm2

standing.

Adjacent side walls which project above hob level, must not be nearer to the cooker than 150mm and should be protected by heat resistant material.

Any overhanging surface or cooker hood should not be nearer than 650mm.

Before moving your cooker check that it is cool, and switch off at the cooker control unit.

Movement of your cooker is most easily achieved by lifting the front as follows:

Open the grill door sufficiently to allow a comfortable grip on the underside front edge of the oven roof, avoiding any grill elements.

Note: Take care in moving the cooker as it is heavy. Take care to ensure that any floor covering is not damaged.

Splashplate optional, apply to Parts Department (see Back Cover for contact number.)

5

Page 5
Image 5
Indesit IT50E1 S Installation, Electrical connection, Warning - This Appliance Must Be Earthed, Positioning the Cooker