Specs
PWOK Signal Characteristics
Field Replacement Unit FRU Signals
Optional Server Signal Connector
Temperature Requirements
Control and Indicator Functions
Required Baseboard power connector
Optional Chassis Mounting Features
Page 1
Image 1
SSI
ERP2U
(Entry Redundant Power 2U)
Power Supply Design Guide
A Server System Infrastructure (SSI) Specification
For 2U Rack Chassis Power Supplies
Version 1.0
Page 2
Page 1
Image 1
Page 2
Contents
A Server System Infrastructure SSI Specification
ERP2U Entry Redundant Power 2U Power Supply Design Guide
For 2U Rack Chassis Power Supplies
Version
Disclaimer
Purpose
Contents
Conceptual Overview
Definitions/Terms/Acronyms
Tables
Figures
MTBF
Agency Requirements
2 Conceptual Overview
1 Purpose
3 Definitions/Terms/Acronyms
Required Optional
4 Mechanical Overview
Figure 1 Enclosure Drawing
4.2 Airflow Requirements
4.1 Optional Chassis Mounting Features
Optional
Recommended
5.1 AC Inlet Connector
4.3 Temperature Requirements
5 AC Input Requirements
5.2 Redundant AC Inlets
5.4 Efficiency
5.3 AC Input Voltage Specification
47 Hz
63 Hz
5.6 AC Line Fuse
5.5 AC Line Dropout
5.7 AC Inrush
5.9 AC Line Fast Transient Specification
5.8 AC Line Transient Specification
Table 4 AC Line Sag Transient Performance
Table 5 AC Line Surge Transient Performance
6.1 Output Connectors
6 DC Output Specification
6.1.1 Required Baseboard power connector
6.1.2 Optional Processor Power Connector
6.1.4 Required Floppy Power Connector
6.1.3 Required Peripheral Power Connectors
Table 8 Peripheral Power Connectors
Table 9 P9 Floppy Power Connector
6.2 Grounding
6.1.5 Optional Server Signal Connector
6.3 Remote Sense
Table 11 350 W Load Ratings
6.4 Output Power/Currents
Table 12 480 W Load Ratings
6.4.1 Standby Outputs
6.5 Voltage Regulation
6.7 Capacitive Loading
6.6 Dynamic Loading
6.8 Ripple / Noise
Table 15 Transient Load Requirements
6.10 Hot Swap Requirements
6.9 Redundancy
Table 17 Ripple and Noise
DC connect at the same time as the module is inserted into the cage. No damage to the connector contacts shall occur. The module may power on or come up into standby mode
Table 18 Output Voltage Timing
6.11 Timing Requirements
Figure 2 Output Voltage Timing
Table 19 Turn On/Off Timing
Figure 3 Turn On/Off Timing
7.1 Current Limit
7 Protection Circuits
7.2 240VA Protection
7.3 Over Voltage Protection
7.4 Over Temperature Protection
Table 21 Over Current Protection
Table 22 Over Voltage Limits
8.1 PSON#
8 Control and Indicator Functions
Table 24 PWOK Signal Characteristics
8.2 PWOK Power OK
8.3 SMBus Communication
8.3.1 Field Replacement Unit FRU Signals
8.3.2 Module FRU Data
8.3.3 Module FRU Data Format
Field Name PS Info
8.3.3.2 MultiRecord Area
Field Information Definition
LED Indicators
8.4 LED Indicators
POWER SUPPLY CONDITION
Power Supply LEDs
10Agency Requirements
9 MTBF