8.3SMBus Communication

SSI

ERP2U Power Supply Design Guide, V1.0

8.3SMBus Communication

STATUS

Optional

There may be SMBus communication to the power assembly to monitor the cage and modules. This would require a serial EEPROM to store FRU data of each module and communicate the information onto the SMBus. There may also be a device in the cage to monitor the module failure and presence status via the SMBus. If there is a fan in the cage, the SMBus device in the cage may also monitor the fan(s) for failure.

8.3.1Field Replacement Unit (FRU) Signals

STATUS

Optional

Two pins will be allocated for the FRU information on the power supply connector. One pin is the Serial Clock (SCL). The second pin is used for Serial Data (SDA). Both pins are bi-directional and are used to form a serial bus. The FRU circuits inside the power supply must be powered off of 5 VSB output and grounded to ReturnS (remote sense return). The Write Control (or Write protect) pin should be tied to ReturnS inside the power supply so that information can be written to the EEPROM.

8.3.2Module FRU Data

FRU data shall be stored starting in address location 8000h through 80FFh. The FRU data format shall be compliant with the IPMI specifications. The current version of these specifications are available at: http:\\developer.intel.com/design/servers/ipmi/spec.htm.

8.3.3Module FRU Data Format

The information to be contained in the FRU device is shown in the following table.

 

Table 25: FRU Device Information

Area Type

 

Description

Common Header

 

As defined by the FRU document

 

 

 

Internal Use Area

 

Not required, do not reserve

 

 

 

Chassis Info Area

 

Not applicable, do not reserve

 

 

 

Board Info Area

 

Not applicable, do not reserve

 

 

 

8.3.3.1Product Info Area

As defined by the IPMI FRU document. Product information shall be defined as follows:

Table 26: FRU Device Product Information Area

Field Name

Field Description

Manufacturer Name

{Formal name of manufacturer}

 

 

Product Name

{Manufacturer’s model number}

 

 

Product part/model number

Customer part number

 

 

Product Version

Customer current revision

 

 

Product Serial Number

{Defined at time of manufacture}

 

 

 