SSI

 

 

 

 

ERP2U Power Supply Design Guide, V1.0

 

 

Table 19: Turn On/Off Timing

 

 

 

 

 

Item

Description

MIN

 

MAX

UNITS

 

 

Tsb_on_delay

Delay from AC being applied to 5 VSB being

 

 

1500

ms

 

 

within regulation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T ac_on_delay

Delay from AC being applied to all output voltages

 

 

2500

ms

 

 

being within regulation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tvout_holdup

Time all output voltages stay within regulation

18

 

 

ms

 

 

after loss of AC.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tpwok_holdup

Delay from loss of AC to deassertion of PWOK.

17

 

 

ms

 

 

 

 

 

 

 

 

 

Tpson_on_delay

Delay from PSON# active to output voltages within

5

 

400

ms

 

 

regulation limits.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T pson_pwok

Delay from PSON# deactive to PWOK being

 

 

50

ms

 

 

deasserted.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tpwok_on

Delay from output voltages within regulation limits

200

 

1000

ms

 

 

to PWOK asserted at turn on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T pwok_off

Delay from PWOK deasserted to output voltages

1

 

 

ms

 

 

(3.3 V, 5 V, 12 V, -12 V) dropping out of regulation

 

 

 

 

 

 

 

limits.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tpwok_low

Duration of PWOK being in the deasserted state

100

 

 

ms

 

 

during an off/on cycle using AC or the PSON#

 

 

 

 

 

 

 

signal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tsb_vout

Delay from 5 VSB being in regulation to O/Ps

50

 

1000

ms

 

 

being in regulation at AC turn on.

 

 

 

 

 

 

 

 

 

 

 

 

 

STATUS

Recommended

Item

Description

MIN

MAX

UNITS

 

Tvout_holdup

Time all output voltages stay within regulation

21

 

ms

 

 

after loss of AC.

 

 

 

 

 

 

 

 

 

 

Tpwok_holdup

Delay from loss of AC to deassertion of PWOK.

20

 

ms

 

 

 

 

 

 

 

Tsb_holdup

Time 5VSB output voltage stays within regulation

70

 

ms

 

after loss of AC.

 

 

 

 

 

 

 

 

 

 

- 22 -

Page 22
Image 22
Intel ERP2U manual Turn On/Off Timing, Recommended Description