54
2Hardware Installation
2
1
ON
2.6.10 Chassis Open Connector
2
1
Ground
Chassis signal "
The system board supports the chassis intrusion detection func-
tion. To use this function, connect the chassis intrusion sensor
cable from the chassis to J6. Whenever a chassis component has
been removed, the sensor sends signal to J6 alerting you of a
chassis intrusion event. To disable this function, place a jumper
cap over J6.
Hardware Doctor Utility
Install “Hardware Doctor”. By default, the chassis intrusion detec-
tion function is disabled. When enabled, a warning message will
appear when the chassis is open. The utility can also be
configured so that a beeping alarm will sound when the chassis is
open. Refer to the “Hardware Doctor” section in chapter 4 for
more information.