SE7221BK1-ETechnical Product Specification

9)Plug the system into the AC power source and power it up to confirm that the recovery was successful.

Figure 7. BIOS Recovery Jumper

9.7Error Handling and Reporting

9.7.1POST Error Beep Codes

Table 67. POST Error Beep Codes

Beeps

Error Message

POST Progress Code

Description

1

Fatal error

 

System halted because of

 

 

 

an unspecified fatal error

 

 

 

that was detected.

2

Processor error

 

System halted because a

 

 

 

fatal error related to a

 

 

 

processor was detected.

3

Memory error

 

System halted because a

 

 

 

fatal error related to the

 

 

 

memory was detected.

4

Motherboard error

 

System halted because a

 

 

 

fatal error related to the

 

 

 

system motherboard

 

 

 

hardware was detected.

56

Revision 1.3

Page 68
Image 68
Intel SE7221BK1-E Error Handling and Reporting, Post Error Beep Codes, Beeps Error Message Post Progress Code Description