Jackson Tempstar TGP Troubleshooting Section, Use Extreme Caution When Testing The Machine

Models: Tempstar TGP

1 41
Download 41 pages 54.93 Kb
Page 17
Image 17
Manual background

TROUBLESHOOTING SECTION

WARNING: Inspection, testing and repair of electrical equipment should only be performed by a qualified service techni- cian. Many of the tests require that the unit have power to it and live electrical components be exposed.

USE EXTREME CAUTION WHEN TESTING THE MACHINE.

 

 

 

 

 

 

Symptom

Possible Cause

Action

 

 

 

 

 

 

 

Low rinse temperature/low wash

Low inlet water temperature.

Ensure incoming water is 110 F (43.33 C) at

 

 

temperature.

 

incoming point of machine, may need to

 

 

 

 

increase the set point of the supply water

 

 

 

 

heater.

 

 

 

 

 

 

 

 

Low gas pressure.

Check gas supply pressure.

 

 

 

 

 

 

 

 

 

Ensure proper operation of combination gas

 

 

 

 

cutoff valve.

 

 

 

 

 

 

 

 

 

Ensure manual gas cutoff valve is open.

 

 

 

 

 

 

 

 

 

Check gas supply pressure.

 

 

 

 

 

 

 

 

 

Check for kinks in flexible gas supply line.

 

 

 

 

 

 

 

 

Improper circulation through system.

Check recirculating pump operation. Check

 

 

 

 

for obstructions.

 

 

 

 

 

 

 

 

T-set needs adjustment.

Ensure set point is approximately 4.25 VDC.

 

 

 

 

 

 

 

 

Defective T-mid thermistor (Red LED light

Check Ohms reading is between 950 and

 

 

 

may be flashing).

1150 Ohms when probe is at room

 

 

 

 

temperature. Check for frayed wiring.

 

 

 

 

Ensure connection to control board.

 

 

 

 

 

 

 

 

Defective control board (ECB).

Perform auto-calibration. Ensure power

 

 

 

 

supplied to board is +12 VDC. Ensure green

 

 

 

 

LED light is flashing.

 

 

 

 

 

 

 

High rinse temperature.

T-set needs adjustment.

Ensure set point is approximately 4.25 VDC.

 

 

 

 

 

 

 

 

ECO failure. (Overprotection feature is

Remove wire from ECO terminal. If burner

 

 

 

faulty and does not open at 210 F) (98.89

unit turns off, ECO may be defective.

 

 

 

C).

Replace ECO.

 

 

 

 

 

 