TROUBLESHOOTING SECTION
WARNING: Inspection, testing and repair of electrical equipment should only be performed by a qualified service techni- cian. Many of the tests require that the unit have power to it and live electrical components be exposed.
USE EXTREME CAUTION WHEN TESTING THE MACHINE.
|
|
|
|
Symptom | Possible Cause | Action |
|
|
|
|
|
Dishmachine will not run. No power to the | Service breaker tripped. | Reset breaker. If breaker trips again, |
|
unit. |
| immediately contact an electrician. |
|
|
|
|
|
| Incoming power lines not installed in control | Install power lines. |
|
| box. |
|
|
|
|
|
|
| Incoming power lines connections not | Tighten connections. |
|
| tightened. |
|
|
|
|
|
|
Dishmachine will not run. There is power to | Door switch shorted out or is disconnected. | Check to ensure door switch wires are |
|
the unit. |
| connected correctly. If so, replace door |
|
|
| switch. |
|
|
|
|
|
| Misadjusted or faulty "cycle reset" cam | Replace microswitch. |
|
| microswitch. |
|
|
|
|
|
|
Machine runs, but there is not water. | No water supply to machine. | Check to ensure that all water valves are |
|
|
| open and that water is being supplied to the |
|
|
| machine at 20 PSI. |
|
|
|
|
|
| Incoming water supply solenoid not | Check to ensure that valve is wired |
|
| operating. | correctly. If so, replace valve. |
|
|
|
|
|
Dishmachine fills continuously, even when | Incoming water supply solenoid not | Check to ensure that valve is wired |
|
the machine is off. | operating. | correctly. If so, replace valve. |
|
|
|
|
|
Dishmachine fills continuously, only when | Incoming water supply solenoid not | Check to ensure that valve is wired |
|
the power is on. | operating. | correctly. If so, replace valve. |
|
|
|
|
|