Fully Integrated Grille Installation Requirements

Fully Integrated Grille Installation Requirements

The refrigerator can be installed fully integrated if the adjacent cabinetry meets the airflow venting requirements critical to refrigerator performance. A Fully Integrated Grille installation has no visible air gap because the grille extends upward to the soffit or upper cabinet.

IMPORTANT:

A Fully Integrated Grille installation requires a minimum of 6" (15.24 cm) of open space above the refrigerator. This space must not be blocked in any way, including by soffits.

Both Standard and Fully Integrated Grille installations can be achieved with either a 24" (60.9 cm) or 25" (63.5 cm) deep opening.

A full height grille is used to achieve a Fully Integrated Grille installation. Use the integrated bracket (provided with refrigerator) to attach the full height grille.

NOTE: A top grille filler is not required with a full height grille.

Integrated Grille Bracket

Fully Integrated Grille Installation—Side View

Integrated Grille Bracket A

B

Fully Integrated Grille Installation—Side View C

 A D

A. False front (optional)

C. Full height grille

B. Airflow

D. Door panel

Fully Integrated Grille Installation Options

Option 1—Open to Ceiling

6" (15.24 cm)

min.

84"

(213.4 cm)

Option 2—False Front (cabinet face only)

6" (15.24 cm)

min.

84"

(213.4 cm)

11