Jenn-Air W10379136B Install Anti-TipBoards, Connect the Water Supply, To Install Anti-tipBoards

Models: W10379136B

1 72
Download 72 pages 44.85 Kb
Page 15
Image 15
Install Anti-Tip Boards

Install Anti-Tip Boards

IMPORTANT:

If a solid soffit is not available, an anti-tip board must be installed.

It is recommended that board(s) be installed before the refrigerator is installed.

Board(s) must be long enough to fully cover the width of the compressor cover.

Locate the board(s) so the bottom surface(s) of the board(s) is(are) 84" (213 cm) from the floor.

During installation, raise the refrigerator up until the top of the refrigerator is making contact with the bottom of the anti-tip board(s). Do not crush the compressor cover when raising the rear leveling legs.

To Install Anti-tip Boards

1.Mark the stud locations on rear wall 80" to 90" (203 cm to 229 cm) above floor.

2.Securely attach one or two 2" x 4" x 32" (5 cm x 10 cm x 81 cm) boards to wall studs behind refrigerator. Use six #8 x 3" (7.6 cm) (or longer) wood screws. The wood screws must be screwed into the studs at least 1½" (3.8 cm). The board(s) must overlap the compressor cover.

A B

To Install Anti-tip BoardsA BConnect the Water SupplyConnect to Water LineStyle 1—Shutoff Valve ConnectionManual backgroundManual background C

¹⁄₄" (6 mm) max.

2" (5 cm) Manual background

84"

(213.4 cm)

D

E

A. Center board ¹⁄₄" (6.35 mm) max. above refrigerator

B. Two 2" x 4" x 32" (5 cm x 10 cm x 81 cm) boards

C. Attach to studs with six #8 x 3" (7.6 cm) screws

D. Compressor cover

E. Distance from bottom of anti-tip board to floor

Connect the Water Supply

Read all directions before you begin.

IMPORTANT: If you turn the refrigerator on before the water line is connected, turn the ice maker OFF.

Connect to Water Line

Parts Needed:

Minimum 7 ft (2.13 m) flexible, codes approved water supply line

Style 1—Shutoff Valve Connection

NOTE: If your water line connection does not look like Style 1, see “Style 2—Copper Line Connection.”

1.Unplug refrigerator or disconnect power supply.

IMPORTANT: Before attaching the tubing to shutoff valve, flush the main water supply line to remove particles and air in the water line. Allow enough flow so that water becomes clear. Flushing the water line may help avoid filters and/or water valves from becoming clogged.

2.Connect the flexible, codes approved water supply line to the water shutoff valve by threading the provided nut onto the shutoff valve as shown.

A

B

C

A.Bulb

B.Nut

C.Water tubing

3.Place the end of the tubing into a bucket, and turn shutoff valve ON.

4.Check for leaks. Tighten any nuts or connections (including connections at the valve) that leak.

15

Page 15
Image 15
Jenn-Air W10379136B manual Install Anti-TipBoards, Connect the Water Supply, To Install Anti-tipBoards, A B C