Read Enclosure Configuration Command
Read enclosure status is a mandatory SAF-TE command that reports to the host
what components are installed in the enclosure. This will only read the unit that
the SEP is installed on, not any unit connected via S-Link.The components that
can be monitored are listed below:
Number of Fans
Reports the number of currently installed cooling fans.
Number of Power Supplies
Reports the number of currently installed power supplies.
Number of Device Slots
Reports the total number of device slots available in the unit whether or
not a device is inserted.
Door Lock Installed
Reports whether or not a door lock is installed. If there is a lock installed,
the remote lock/unlock feature is a manual procedure and is not host-
controllable.
Number of Temperature Sensors
Reports the number of temperature sensors installed.
Speaker Installed
Reports if a speaker or buzzer is installed in the unit.
Read Enclosure Status Command
Read enclosure configuration is a mandatory SAF-TE command. This command
is used to find the status of the enclosure components that are listed by the 'Read
Enclosure Configuration Command'. The components and possible status values
are listed below:
FORTRAH1 Chaparral G5312 InstallationGuide Rev C 9-15
Blower Power Supply Slot SCSI ID Door Lock Speaker Temperature
Operational Operational and on Slot 'x' = SCSI Installed Off Temperature in Fahrenheit
ID 'x' from -10 to 245
Malfunctioning Operational and off Not On Out of Range
Installed
Not Installed Malfunctioning and
commanded on
Unknown Malfunctioning and
commanded off
Not Present
Present (on or off)
Unknown