Jotul Woodstove F 400 manual Jøtul F 400 Woodstove Clearances, USA/Canada, Stove

Models: Woodstove F 400

1 68
Download 68 pages 24.18 Kb
Page 9
Image 9

USA/Canada

Jøtul F 400 Woodstove Clearances

Stove

Unprotected Surface

 

Protected Surface Installation

Clearances

Installation

 

PER NFPA211 OR CAN/CSA -B365-M93

 

 

 

 

 

 

 

 

 

 

 

 

Stove -no heatshield

Side

Rear

 

Corner*

Side

 

 

Rear

 

Corner*

19" A

25" B

 

18" C

11” D

 

 

7" E

 

8" F

single wall pipe

485mm

635mm

 

460mm

280mm

 

180mm

205mm

 

 

 

 

 

 

 

 

 

 

 

 

Stove -with rear heatshield

18" G

18" H

 

13" I

11” J

 

 

7” K

 

8" L

single wall pipe

460mm

460mm

 

330mm

280mm

 

180mm

205mm

 

 

 

 

 

 

 

 

 

 

 

 

 

Stove -no heatshields

16”

 

19”

 

13”

8”

 

 

7”

 

6”

double wall pipe

405mm

485mm

 

330mm

205mm

 

180mm

150mm

 

 

 

 

 

 

 

 

 

 

 

 

Stove -with rear heatshield

15" M

7" N

 

11" O

8" P

 

 

7" Q

 

6" R

with connector shield

380mm

180mm

 

280mm

205mm

 

180mm

150mm

 

 

 

 

 

 

 

 

 

 

 

 

Stove -rear heatshield

15" S

7" T

 

11" U

8" V

 

 

7" W

 

6" X

with double wall pipe

380mm

180mm

 

280mm

205mm

 

180mm

150mm

 

 

 

 

 

 

 

 

 

Connector

Unprotected Surface

 

Protected Surface

 

Clearances (Pipe)

Vertical Installation

per NFPA211

Vertical Inatallation

 

 

 

 

 

 

 

OR CAN/CSA-B365-M93

 

Single wall pipe

25"

 

 

 

 

12"

 

 

 

 

 

 

 

635mm

 

 

 

300mm

 

 

 

Single wall pipe

18”

 

 

 

 

7”

 

 

 

 

 

with rear heatshield

460mm

 

 

 

180mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single wall pipe

7"

 

 

 

 

7"

 

 

 

 

 

with connector shields

180mm

 

 

 

180mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Double wall pipe

7"

 

 

 

 

7"

 

 

 

 

 

 

 

180mm

 

 

 

180mm

 

 

 

Connector

Unprotected Surface

 

Protected Surface

 

Clearances (Pipe)

Horizontal Installation

Horizontal Installation

 

 

 

 

 

 

 

 

per NFPA211 OR CAN/CSA-B365-M93

Single wall connector

18"

460mm

 

7"

180mm

 

 

 

Double wall Pipe

6"

150mm

 

6"

150mm

 

 

 

 

 

 

 

 

 

 

 

 

 

Mantel and Trim

Stove to 1" thick or less, side trim

 

 

 

13"

300mm

 

Clearances

Stove to 1" thick or less, top trim

 

 

 

23"

585mm

 

 

 

Stove to mantel- maximum mantel depth 12"

25"

635mm

 