Configuring the Chassis Alarm

For example, if you assigned the MGT interface an IP address of 10.100.2.183/16, enter the following:

http://10.100.2.183

The NetScreen WebUI software displays the login prompt.

3.Enter netscreen in both the Admin Name and Password fields, then click Login. (Use lowercase letters only. The Admin Name and Password fields are both case sensitive.)

The NetScreen WebUI application window appears.

CONFIGURING THE CHASSIS ALARM

The NetScreen-5000 Series device allows you to configure the chassis alarm, an audible warning that sounds when a system failure or hazardous event occurs. To determine which failures and events trigger the chassis alarm:

1.Configure the audible alarms by executing the following command: set chassis audible-alarmstring

where string can be any of the following keywords:

all

Enables all chassis alarms.

battery

Sets the chassis alarm to sound when a battery fails.

fan-failed

Sets the chassis alarm to sound when a fan fails.

power-failed

Sets the chassis alarm to sound when a power supply fails.

temperature

Sets the chassis alarm to sound when the temperature goes outside of

 

the acceptable range.

2.After configuring the alarm, it is advisable to view alarm environment information by executing the following command:

get chassis