Getting Alarm Trigger
Format /api/param?application.event(Number).trigger
Example When Getting Trigger of Alarm No. 1
/api/param?application.event(1).trigger
Example of Response application.event(1).trigger=m1&200 OK
Interpretation Acquire Trigger of the alarm action for the specified alarm number. Up to 5 alarm actions can be specified, periodic FTP is assigned to event No.6, pre/post FTP assigned to No.7, SD Card constant recording to event No.8 and SD Card alarm recording to No.10. Therefore the number of event(number) can be set between the range of 1 to 8 and 10. Note that alarm numbers are different from the alarm input pin numbers.
When only 1 Trigger is set:
m1 will be returned in the case of make for alarm input 1.
m2 will be returned in the case of make for alarm input 2.
v1 will be returned for motion detection of video.
audio_detect1 will be returned for audio detection1.
ncbwe will be returned for IR filter ON. ncbws will be returned for IR filter OFF. i(second) will be returned for periodic FTP trigger. time/hhmmss will be returned for time trigger.
When a combination of 2 Triggers are set, responses such as m1(10)b2 will be returned. The example indicates that trigger will be activated when break is invoked at alarm input 2 within 10 seconds after make is invoked at alarm input 1.
Example of Response application.event(1).trigger=m1(100)b2&200 OK
Allowed users admin, operator
Setting Alarm Trigger
Format /api/param?application.event(Number).trigger=data
Example When setting Trigger of Alarm No. 1
/api/param?application.event(1).trigger=m1
Example of Response
43