JVC GR-DVM80, GRDVM80U 62 EN, Corrective Action, TROUBLESHOOTING cont, Symptom, Possible Causes

Models: GR-DVM80

1 76
Download 76 pages 60.05 Kb
Page 62
Image 62
62 EN

62 EN

TROUBLESHOOTING (cont.)

SYMPTOM

 

POSSIBLE CAUSES

 

35. The LCD monitor image is

 

35. • During playback of the

 

distorted.

 

unrecorded portion, High-speed

 

 

 

Search and still playback, LCD

 

 

 

monitor indications appear

 

 

 

distorted. This is not a defect.

 

36.Images on the LCD monitor 36. • The speaker volume is too great. are jittery.

37.

Blocks of noise appear

37.

 

during playback, or there is

————

 

no playback picture and the

 

 

 

screen becomes blue.

 

 

 

 

38.

The LCD monitor, the

38.

 

viewfinder and the lens have

————

 

become dirty (ex. fingerprints).

 

 

 

 

39.

An unusual mark appears.

39.

 

 

————

 

 

 

40.

An error indication

40. • A malfunction of some kind

 

(E01 — E06) appears.

has occurred. In this case the

 

 

camcorder’s functions

 

 

become unusable.

41.The charger indicator on the 41. • The temperature of the battery

 

AC Power Adapter/Charger

 

is extremely high/low.

 

does not light.

 

• Charging is difficult in places

 

 

 

subject to extremely high/low

 

 

 

temperatures.

 

 

 

 

42.

Picture does not appear on

42.

• The viewfinder is pulled out.

 

the LCD monitor.

 

• The LCD monitor's brightness

 

 

 

setting is too dark.

 

 

 

 

43.

When the image is printed

43.

• This is not a malfunction.

 

from the printer, a black bar

 

 

 

appears at the bottom of the

 

 

 

screen.

 

 

 

 

 

 

44.

When the camcorder is

44.

• The DV cable was plugged/

 

connected via the DV

 

unplugged with power turned

 

connector, the camcorder

 

on.

 

does not operate.

 

 

 

 

 

 

45.

During transport, the lens

45.

 

 

cover opens.

 

————

 

 

 

CORRECTIVE ACTION

35.

————

36.• Turn the speaker volume down ( pg. 36).

37.•Clean the video heads with an

optional cleaning cassette ( pg. 70).

38.• Wipe them gently with soft

cloth. Wiping strongly can cause damage ( pg. 57).

39.• Check the section of the manual that explains LCD

monitor/viewfinder indica- tions ( pg. 66 – 68).

40.• Remove the power supply (battery pack, etc.) and wait a few minutes for the indication to clear. When it does, you can resume using the camcorder. If the indication remains even though you repeat the above two or three times, please consult your nearest JVC dealer.

41.• To protect the battery, it is recommended to charge it in places with a temperature of

10°C to 35°C (50°F to 95°F) ( pg. 69).

42.• Push the viewfinder back in.

Adjust the brightness of the LCD monitor ( pg. 16).

If the monitor is tilted upward

180 degrees, open the monitor fully ( pg. 16).

43.• By recording with “DIS” activated ( pg. 26) this can be avoided.

44.• Turn the camcorder’s power off

and on again, then operate it.

45.• Do not subject the camcorder to shock or excessive vibration during transport.

Turn the camcorder on and off. The lens cover closes.

Page 62
Image 62
JVC GR-DVM80, GRDVM80U specifications 62 EN, Corrective Action, TROUBLESHOOTING cont, Symptom, Possible Causes