7. OTHERS (Cont’d)
TECHNICAL INFORMATION (Cont’d)
SYNC mode can be switched over with the SW3 of set up switch.
MODE |
| SWITCH SETTING | ||||||
|
|
|
|
|
|
|
| |
SYNC | ↑ | 1 | 2 | 3 | 4 |
| 3: ON | |
Non Reset mode | NO |
|
|
|
|
|
| 1, 2, 4: Do not switch over |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
SYNC | ↑ | 1 | 2 | 3 | 4 |
| 3: OFF | |
Reset mode | NO |
|
|
|
|
|
| 1, 2, 4: Do not switch over |
|
|
|
|
|
|
| ||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
Note:
Before switching the set up switch turn the power switch to off. The mode will not change when the power is switched ON.
CAMERA CONTROL UNIT KY-F58
LOCK | MENU | ITEM+ | DATA+ |
| FILES | FREEZE | ||
1 | 2 | 3 | 4 | |||||
ON |
|
|
| |||||
|
|
|
|
|
|
| ||
|
| BARS |
|
|
|
| ||
1 2 3 4 RESET | SET | ITEM- | DATA- | SELECT |
|
| MEMORY |
ON | OFF | POWER |
TO CAMERA | WHITE PAINT | VIDEO LEVEL |
SET | FULL AUTO | LEVEL |
|
| ON |
RB
OFF
PAINT
Trigger signal
Electric charge to be stored in CCD
SYNC Non Reset Mode
Camera video output signal
WEN signal
SYNC Reset Mode
Camera video output signal
WEN signal
FLASH Function
When the FREEZE item is set to FLASH, the signal is output from the FLASH terminal on the rear panel for the FREEZE input.
The following conditions are provided to the output signal.
FREEZE IN
Approx. 1H
FLASH OUT
6H
1 FLASH OUT signal is output from the FREEZE IN in approx.1H.
2The width of the FLASH OUT is 6H.
3The FLASH OUT signal is output as open corrector. Pull up the voltage at 15 V DC or less at the receiving termi- nal.
28Revised in August 1998
Random Trigger Function
This is used to detect an object in order to recognize the image.
When the trigger signal detecting object is input, an electric charge is stored in the CCD image device on the camera, and it is output syncronized with the next SYNC signal. At this time an WEN signal is also output to be used for the memory latch. On a monitor, the movement of the object looks like when taken under a strobe shot.
Two modes can be selected by the output timings of the cam- era corresponding to the trigger input signals.
1.SYNC Non Reset Mode
This is a system to output the camera timing regardless of the trigger input signal. When the camera is in the GENLOCK mode, timing is output synchronized with the input signal of the GENLOCK IN.
2.SYNC Reset Mode
This is a system to output the timing by synchronizing with the trigger input signal.
In this case, the trigger signal is the standard signal of a structured system, so that the GENLOCK function will not be carried out.
[U Ver.]
VD IN
HD IN | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 11 12 13 14 15 16 17 18 |
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Prohibited section (12H)
FREEZE IN
FLASH OUT
6H
[E Ver.]
VD IN
HD IN
Prohibited section (23H)
FREEZE IN
FLASH OUT
6H
4There is a prohibited section of 12H [U Ver.] or 23H [E Ver.] at the section where the image changes. A FREEZE signal in the prohibited section (12H [U Ver.] or 23H [E Ver.]) is output as a FLASH OUT when the prohibited sec- tion is ended.
V.SYNC
Prohibited | Prohibited | Prohibited |
FREEZE IN
FLASH OUT
5When a FREEZE signal is input continuously, input from the first to third V. SYNC will not be accepted and FLASH OUT is not output.