OPERATION (continued)

W.PAINT

GAIN SHUTTER IRIS MANU OPERATE

ENTER

MENU FUNC1 FUNC2 /SET

B C D E

oGENLOCKING MODE ADJUSTMENTS

Controls SC phase and horizontal phase during genlocking

1.Select A3: SC FINE COARSEB using MENU button B (SC phase adjustment).

3 : SC FINE COARSE

0 0°

SC FINE SC COARSE

2.Set the SC COARSE using FUNC2 button D (0°, 90°, 180° and 270°).

3.Fine-adjust the SC phase using FUNC1 button C (–128 to +127).

Select ASC COARSEB

To fine-adjust in the +

 

direction.

FUNC1 FUNC2

 

To fine-adjust in the – direction.

If the button is held depressed, the level will vary in 10 steps.

4.Select A4: H.PHASEB using MENU button B (horizontal phase adjustment).

4 : H. PHASE

0

Horizontal phase

5.Adjust the horizontal phase using FUNC1 button C (–128 to +127).

If the button is held depressed, the level will vary in 10 steps.

To adjust phase in the

 

+ direction.

FUNC1

 

To adjust phase in the

– direction.

oGAMMA CORRECTION (ON/OFF)

Set to ON to correct gamma or to OFF when gamma correction is not required.

1.Select A5: GAMMAB using MENU button B.

2.Set to ON or OFF using FUNC2 button D.

Set ON or OFF.

FUNC2

5 : GAMMA

ON

Mode indication

oAUTO IRIS DETECTION MODE

Three modes are available:

NORMAL

: Detection is based on a

 

combination of peak value and

 

average value.

PEAK

: The peak value is detected, and

 

the optimum iris level is

 

adjusted.

AVG

: The average value is detected,

 

then the optimum iris level is

 

adjusted.

1.Select A6: IRIS DETECTB using MENU button

B.

6 : IRIS DETECT NORMAL

2.Select the detection mode using FUNC2 button

D.

Each time is pressed, the mode changes from NORMAL N PEAK N AVG N NORMAL N...; pressing changes the modes in reverse order.

Select a detection

mode.FUNC2

E-8

Page 8
Image 8
JVC RK-LP55U manual Genlocking Mode Adjustments, Gamma Correction ON/OFF, Auto Iris Detection Mode