E-8
OPERATION (continued)
oGENLOCKING MODE ADJUSTMENTS
Controls SC phase and horizontal phase
during genlocking
1. Select A3: SC FINE COARSEB using MENU
button B (SC phase adjustment).
2. Set the SC COARSE using FUNC2 button D
(0°, 90°, 180° and 270°).
3. Fine-adjust the SC phase using FUNC1 button
C (–128 to +127).
If the button is held depressed, the level will
vary in 10 steps.
4. Select A4: H.PHASEB using MENU button B
(horizontal phase adjustment).
5. Adjust the horizontal phase using FUNC1
button C (–128 to +127).
If the button is held depressed, the level will
vary in 10 steps.
oGAMMA CORRECTION (ON/OFF)
Set to ON to correct gamma or to OFF when
gamma correction is not required.
1. Select A5: GAMMAB using MENU button B.
2. Set to ON or OFF using FUNC2 button D.
oAUTO IRIS DETECTION MODE
Three modes are available:
NORMAL : Detection is based on a
combination of peak value and
average value.
PEAK : The peak value is detected, and
the optimum iris level is
adjusted.
AVG : The average value is detected,
then the optimum iris level is
adjusted.
1. Select A6: IRIS DETECTB using MENU button
B.
2. Select the detection mode using FUNC2 button
D.
Each time is pressed, the mode changes
from NORMAL N PEAK N AVG N NORMAL
N...; pressing changes the modes in
reverse order.
W.PAINT GAIN SHUTTER IRISMANU OPERATE
FUNC1MENU
ENTER
/SET
FUNC2
BDCE
3 :
SC FINE COARSE
0°0
SC FINE SC COARSE
FUNC1 FUNC2
To fine-adjust in the +
direction.
To fine-adjust in the –
direction.
Select ASC COARSEB
4 : H. PHASE
0
Horizontal phase
FUNC1
To adjust phase in the
+ direction.
To adjust phase in the
– direction.
Set ON or OFF.
5 : GAMMA
ON
Mode indication
FUNC2
6 : IRIS DETECT
NORMAL
FUNC2
Select a detection
mode.
RM-LP55_U_E.book Page 8 Monday, July 25, 2005 2:57 PM