MENU SETTING
MOTION DETECT Screen
Settings are executed about the motion detecting function that emits alarm signals when there exists any motion in the image. Alarm signals are output from the auxiliary terminals on the back.
Item |
| Functions and set values | Initial value |
|
|
|
|
MODE | This sets ON/OFF of motion detecting function. | OFF | |
| OFF: | Motion detecting function does not work. |
|
| ON: | Motion detecting function works. |
|
|
|
|
|
LEVEL | This sets the level that detects motion. | NORMAL | |
| If the item MODE is set to OFF, “- - |
| |
| settings cannot be changed. |
| |
| To function with large signal level change…decrease the |
| |
| value |
|
|
| To function with small signal level change…increase the |
| |
| value |
|
|
| [Set values: |
| |
|
|
|
|
AREA EDIT | This sets the range in which the motion detecting function | – | |
| works. |
|
|
| ( Page 39) |
| |
|
|
|
|
ALARM TIME | This sets the output time of the alarm signal output of | 10s | |
| AUX terminal as well as “ALARM” display on the screen |
| |
| when motion is detected. |
| |
| If the item MODE is set to OFF, “- - |
| |
| settings cannot be changed. |
| |
| [Set values: OFF, 5s, 6s, 7s, 8s, 9s, 10s, 15s, 20s, 30s, |
| |
| 1min] |
|
|
| MEMO |
|
|
| Even when the ALARM TIME item is set to OFF, an alarm |
| |
| signal is output from the AUX terminal for about 500ms, |
| |
| and “ALARM” is not displayed on the screen. |
| |
|
|
|
|
DEMONSTRATION | This is used when checking and confirming the set motion | – | |
| detecting function. The detection area is shown in gray. |
| |
| ( Page 39) |
| |
|
|
|
|