Controls, Connectors and Indicators (continued)

(Side and rear views)

90 !

#$ %

RESET

IRIS

@

 

 

 

1

2

ISOLATED POWERONLY

 

DC12V

AC24V

CLASS 2 ONLY ForUSA

For EUROPE

POWER MONITOR OUT

G

2

1

OUT COM

INPUT

 

 

OUTPUT

 

ALARM

PUSH

 

 

 

10BASE-T/100BASE-TX

DO NOT CONNECT TO THE

TELEPHONE NETWORK

For USA

9Ventilation opening

For the internal cooling fan. Install the cam- era in a way that does not cover the opening.

0[RESET] button

Press this button to reset VN-C11. If this but- ton is held down for 2 seconds or longer, the values set with [V.Networks Setup Tool] re- turn to those set at the factory, and VN-C11 restarts.

![IRIS] terminal

For connecting with a DC IRIS lens.

(A video iris lens cannot be connected.)

@[POWER] indicator

This indicator starts blinking when the power is turned on. When the camera is ready for network connection, this becomes steady on. If the indicator blinks while the camera is in use, check the camera and/or the network equipment.

&^

#[DC 12 V/AC 24 V] Power terminal

For connecting to a DC 12 V or AC 24 V, 50 Hz/ 60 Hz, power source. (Page 13)

$[ALARM INPUT] terminals

For connecting with an external alarm equip- ment.

%[ALARM OUTPUT] terminals

For connecting with an external alarm equip- ment.

^[10 BASE-T/100 BASE-TX]

For network connection with a LAN cable. (Page 14)

&[MONITOR OUT] terminal

For connecting to monitor TV when deciding camera angles.

Caution

For angle adjustment only, problems such as noise may occur if connected with a switcher.

9

Page 9
Image 9
JVC VN-C11 manual Side and rear views