Controls, Connectors and Indicators (continued)
(Side and rear views)
90 !
#$ %
RESET | IRIS | @ |
|
|
| 1 | 2 | ISOLATED POWERONLY |
|
DC12V | AC24V | CLASS 2 ONLY ForUSA | For EUROPE |
POWER MONITOR OUT
G | 2 | 1 | OUT COM |
INPUT |
|
| OUTPUT |
| ALARM | ||
PUSH |
|
|
|
DO NOT CONNECT TO THE
TELEPHONE NETWORK
For USA
9Ventilation opening
For the internal cooling fan. Install the cam- era in a way that does not cover the opening.
0[RESET] button
Press this button to reset
![IRIS] terminal
For connecting with a DC IRIS lens.
(A video iris lens cannot be connected.)
@[POWER] indicator
This indicator starts blinking when the power is turned on. When the camera is ready for network connection, this becomes steady on. If the indicator blinks while the camera is in use, check the camera and/or the network equipment.
&^
#[DC 12 V/AC 24 V] Power terminal
For connecting to a DC 12 V or AC 24 V, 50 Hz/ 60 Hz, power source. (☞ Page 13)
$[ALARM INPUT] terminals
For connecting with an external alarm equip- ment.
%[ALARM OUTPUT] terminals
For connecting with an external alarm equip- ment.
^[10
For network connection with a LAN cable. (☞ Page 14)
&[MONITOR OUT] terminal
For connecting to monitor TV when deciding camera angles.
Caution
For angle adjustment only, problems such as noise may occur if connected with a switcher.