Connecting the Power Cord

Connect the camera to DC 12 V or AC 24 V.

To

Power

 

1

2

ISOLATED POWER ONLY

 

 

G

2

1

OUT COM

DC12V

AC24V

CLASS 2 ONLY ForUSA

For EUROPE

INPUT

 

 

 

OUTPUT

 

 

 

 

 

 

 

ALARM

 

 

 

 

 

 

PUSH

 

 

 

Power

 

 

indicator

POWER MONITOR OUT

 

lamp

10BASE-T/100BASE-TX

 

DO NOT CONNECT TO THE

 

 

 

 

TELEPHONE NETWORK

 

 

For USA

The power indicator is lit when the power is turned on.

Power Cord

¥Do not connect the power cord to DC 12 V and AC 24 V at the same time.

¥Use a lug plate to securely connect the power cord to the power terminals and avoid misconnection or loose connection.

¥For DC 12 V connection, ensure that the polarities, positive and negative, are correctly oriented.

¥For DC 12 V connection, the ripple voltage should not exceed 50 mV.

Length: 30 m maximum UL1007, UL1015 or equivalent AWG #20 or equivalent, or higher

WARNING

Connect with the appropriate power-supply voltage.The rated voltage for VN-C11 is DC 12 V or AC 24 V, 50 Hz/60 Hz. If a voltage exceeding the rating is supplied, malfunction, or in the worst case, fuming or fire, may be caused.

For AC 24 V, ensure that the primary side is insulated with the secondary one.

For a system with multiple VN-C11s

In a system where more than one VN-C11 are used, turn on the power for a VN-C11 first and proceed the setting to Other Settings with V.Networks Setup Tool. Only then turn on the power for a second one and go on to Other Settings with V.Networks Setup Tool. Repeat the procedure for the other cameras. Refer to the PDF instruction manual inside the supplied CD-ROM.

Note

The IP address of VN-C11 is set to Ò198.168.0.2Ó at the factory. Proper access cannot be established due to IP address redundancy if the power is turned on for multiple cameras at one time under a single LAN environment. Do not turn on the power for multiple cameras at the same time. If an IP address redundancy occurred, ensure that only one VN-C11 exists on a single LAN environment and wait for some time (at least 10 minutes). Or turn off the power once for all network equipment and turn it on again for proper access to VN-C11.

13

Page 13
Image 13
JVC manual Power Cord, For a system with multiple VN-C11s