VR-N100U USERS MANUAL
Page 82 of 98 All Items Are Subject To Change Without Notice Feb. 2004 Rev 1.0
6.2.6. CN22: Software Reset
Pin Signal
1 Reset
2 GND
The software reset is a means to manually reset the appliance temporarily back to manufacturer’s default settings.
NOTE: VR-N100U rackmount systems do not utilize the manual soft ware reset option.
6.3. BIOS
The settings for the customized Phoenix-Award BIOS for the industrial server board have been optimized for the VR-N100U
security application. No changes to the CMOS are required.
6.4. Adaptec SCSI BIOS
The onboard Adaptec S CSI BIOS settings for the server board ha ve been for the VR-N10 0U security applicati on. No changes
to the Adaptec SCSI BIOS are required. The default settings are:
Adaptec Settings Defaults
SCSI Controller ID 7
SCSI Controller Parity Enabled
SCSI Controller Termination Enabled
Sync Transfer Rate (SCSI ID #0~15) 160 MB/Sec
Initiate Wide Negotiation Yes
Enable Disconnection Yes
Send Start Unit Command Yes
BIOS Multiple LUN Support No
Include in BIOS Scan Yes
Reset SCSI Bus at IC Initialization Enable
Display <Ctrl><A> Message During BIOS Initialization Enable
Extended Init 13 Translation for DOS Drives > 1 GByte Enable
POST Display Mode Verbose
SCSI Controller Int 13 Support Enabled
Domain Validation Enabled
Support Removable Disks Under Int 13 as Fixed Disabled