GEARBOX LUBRICATION
Fig.25
Check the Gearbox oil level every 80 hours of operation. The oil level dipstick/breather is located on the top of the Gearbox.
PREFERRED
•AMOCO PERMAGEAR EP220 OPTIONS
•TEXACO MEROPA
•PETROCAN ULTIMA EP220
After the initial operating period of 500 hours, or 6 months, the oil should be drained, while it is warm, and the Gearbox refilled with new oil.
Under normal operating conditions the Gearbox Oil should be changed every 2500 hours, or 6 months, whichever occurs first.
NOTE
If the Mower is operating in abnormally high ambient temperatures, or contaminated atmosphere, the oil should be changed more frequently.
31
Fig.25
NOTE
The Gearbox illustrated above is fitted on Kesmac Mowers from Serial Number 366.