IMPORTANT: your Kenmore Natural Gas Grill can- not be converted to use LP Gas. Attempting to do so is extremely hazardous and will also void the grill warranty.
Figure 1 (Natural gas model only)
GAS SUPPLY
iNSiDE
WALL
Your natural gas grill is designed to operate on
natural gas only, at a pressure of 7" water column (W.C.) (1/4 psi or 1.75 kpa), regulated at the
OUTSIDE
WALL
TO GRILL
LOCKING
SHUTOFF
residential meter. Check with your gas utility company for local gas pressure and with your
local municipality for building code requirements. If your residential gas line pressure has not been regulated to 7" W.C., contact your local gas utility company for professional assistance.
It is recommended that a Shutoff Valve be installed at the gas supply source outdoors. Install at a point after the gas pipe exits the outside wall and before the
See Figure 1.
•Pipe sealing com pound or pipe thread tape resistant to the action of natural gas must be used on all male pipe threads when making the connection.
Disconnect your gas grill from fuel source when the gas supply is being tested at high pressures. This gas grill and its individual shutoff valve must be disconnected from the gas supply pipe system during any pressure testing of that system at pressure in excess of 1/2 psi (3.5kpa).
Turn off your gas grill when the gas supply is
being tested at low pressures. The grill must be isolated from the gas supply pipe system by closing its individual manual shutoff valve during any pressure testing of the gas supply pipe
system at pressures equal to or less than 1/2 psi (3.5kpa).
SHUT OFF
\
\
\
\
MALE\
FITTING
QUICK
DISCONNECT