Kenwood CK 680 manual 230 V ~, Connecting The Feeder Cable, Feedeer Cable Section, “TYPE H05RR-F”

Models: CK 680

1 36
Download 36 pages 58.34 Kb
Page 33
Image 33
CONNECTING THE FEEDER CABLE

CONNECTING THE FEEDER CABLE

FEEDEER CABLE SECTION

To connect the feeder cable to the cooker

“TYPE H05RR-F”

 

it is necessary to:

230 V

3 x 6 mm2 (**)

 

– Remove the two screws that hold

(**) – Connection with wall box connection.

shield A behind the cooker.

– Contemporaneity factor applied

 

Open completely the cable clamp D.

Insert the mains cable (type H05 RR- F) of minimum 6 mm2 section into the cable clamp D.

Connect the phase and earth cables to terminal B according figure 8.2 and 8.3.

– Pull the feeder cable and block it with

 

 

 

 

 

 

Fig. 8.2

 

 

230 V

 

 

 

the cable clamp D

 

 

 

 

 

 

Re-mount shield A.

 

 

1

2

3

4

5

 

N.B. The earth conductor must be left

 

 

 

 

 

 

 

 

about 3 cm longer than the others.

 

 

 

 

 

 

 

 

 

 

 

 

L1

 

N (L2) PE

 

 

PE

 

Earth

 

 

 

 

 

N

 

Neutral

 

 

 

 

L

 

Live

 

 

 

 

 

 

 

 

 

 

 

Fig. 8.3

 

 

1

2

 

3

4

5

 

 

B

 

 

 

 

N(L2)

 

 

 

 

L1

 

 

PE

 

 

 

 

 

 

 

 

 

 

 

 

230 V ~

 

D

 

Red

 

 

Black

 

Green

 

 

or

 

 

or

 

 

and

 

 

Brown

 

Blue

 

Yellow

Fig. 8.1

A

(Live)

 

(Neutral)

(Earth)

 

 

 

 

 

 

 

 

33

Page 33
Image 33
Kenwood CK 680 manual 230 V ~, Connecting The Feeder Cable, Feedeer Cable Section, “TYPE H05RR-F”, N L2 PE