KitchenAid W10515677C Drain Pump Installation, on some models, Rear View, Kit Contains, Drain Cap

Models: W10515677C

1 60
Download 60 pages 3.76 Kb
Page 6
Image 6
Rear View

Rear View

A

Drain Pump Installation B

(on some models)Kit Contains: C

A. Copper tubing

C. Inlet water tube clamp and

B. Water supply tube clamp

supply line connector

6.Remove and discard the short, black plastic tube from the end of the water line inlet.

7.Thread the nut onto the end of the tubing. Tighten the nut by hand. Then tighten it with a wrench two more turns. Do not overtighten.

NOTE: To avoid rattling, be sure the copper tubing does not touch the cabinet’s side wall or other parts inside the cabinet.

A

B

C

D

A. Line to ice maker

 

C. Ferrule (purchased)

B. Nut (purchased)

 

D. Supplied line from ice maker

8.Install the water supply tube clamp around the water supply line to reduce strain on the coupling.

9.Turn shutoff valve ON.

10.Check for leaks. Tighten any connections (including connections at the valve) or nuts that leak.

Drain Pump Installation

(on some models)

NOTE: Connect drain pump to your drain in accordance with all state and local codes and ordinances. It may be desirable to insulate drain tube thoroughly up to drain inlet to minimize condensation on the drain tube. Insulated tube kit Part Number W10365792 is available for purchase. Drain pump is designed to pump water to a maximum height of 10 ft (3 m). Use only Whirlpool approved drain pump kit Part Number 1901A. Do not connect the outlet end of the drain tube to a closed pipe system to keep drain water from backing up into the ice maker.

Kit Contains:

Drain pump kit Part Number 1901A

⁵⁄₈" ID x 5¹⁄₈" drain tube (ice maker bin to drain pump reservoir inlet)

¹⁄₂" ID x 10 ft (3 m) drain tube hose (drain pump discharge to household drain)

⁵⁄₁₆" ID x 32" (81 cm) vent tube (drain pump reservoir vent to ice maker cabinet back)

Cable clamps (secures vent tube to back of ice maker) (3)

#8-32 x ³⁄₈" pump mounting screws (secures drain pump to baseplate and clamps to back of ice maker) (5)

⁵⁄₈" small adjustable hose clamp (secures vent to drain pump)

⁷⁄₈" large adjustable hose clamp, (secures drain tube to ice maker bin and drain pump reservoir inlet) (3)

Rear panel (2)

Instruction sheet

If Ice Maker Is Currently Installed

NOTE: If ice maker is not installed, please proceed to “Drain Pump Installation” section.

1.Push the selector switch to the Off position.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

2.Unplug ice maker or disconnect power.

3.Turn off water supply. Wait 5 to 10 minutes for the ice to fall into the storage bin. Remove all ice from bin.

4.Unscrew the drain cap from the bottom of the water pan located inside the storage bin. Allow water to drain completely. Replace drain cap. See “Drain Cap” illustration.

Drain Cap

A

A. Drain cap

5.If ice maker is built into cabinets, pull ice maker out of the opening.

6.Disconnect water supply line. See “Water Supply Line” illustration.

6

Page 6
Image 6
KitchenAid W10515677C manual Drain Pump Installation, on some models, Rear View, Kit Contains, Drain Cap, A B C