Plumbing
1.Minimum maintained inlet pressure for satisfactory operation: 0.7 bar
2.Maximum static inlet pressure: 10 bar
3.Minimum static pressure to keep the flow valve closed: 0.5 bar
Electrical
1.The appliance requires a 40 Amp fuse.
2.The terminal block will not accept cable larger than 10 mm2.
Standards andApprovals
1.This Mira Zest shower complies with all the relevant directives for CE marking.
Flow Rate Graph
1.These curves are for the specified outputs at 240 V.
Rise (°C) |
|
Temperature | 8.5 kW |
7.5 kW | |
|
Flow Rate (l/min)
2.All appliance heating elements have a manufacturing tolerance. Flow rates may be above or below those shown on the flow rate graph.
3.The
Temperature rise = (Showering temperature) - (Supply water temperature)
Example: For the Mira Zest 8.5 kW on full power setting with an incoming water supply at 10°C and a showering temperature at 42°C, the temperature rise is 32°C. The flow rate is therefore, 4 l/min.