Malfunction

Cause

Remedy

 

 

 

Water leaks from

The pressure relief valve

Resolve the blocked outlet,

the bottom of the

in the tank has been

and replace the tank

case near the

triggered, (the shower

assembly.

outlet, and there is

has a pressure relief

Reset the relief valve

no flow from the

valve assembly that

handset.

works to reduce the

assembly, refer to

 

damage if the outlet is

Maintenance "Relief Valve

 

blocked or the unit is

Setting"

 

frozen).

 

 

When the relief valve

If the fault persists, contact

 

operates a small rubber

Customer Services.

 

ball is ejected.

 

 

 

 

The water can not

The pilot valve is faulty.

Replace the flow

be turned off.

 

regulator assembly.

 

Broken diaphragm.

Replace the flow regulator

 

 

assembly.

 

The supply pressure is

Contact the local water

 

below the minimum

authority.

 

requirement.

 

 

 

Check the static water

 

 

pressure. Note that the static

 

 

pressure may fall below

 

 

minimum requirement when

 

 

other appliances are drawing

 

 

water; for example, the

 

 

dishwasher or washing

 

 

machine.

 

 

 