Kohler Electric Shower Maintenance Cleaning the, Inlet Filter section, Malfunction, Cause, Remedy

Models: Electric Shower

1 44
Download 44 pages 33.7 Kb
Page 28
Image 28

Malfunction

Cause

Remedy

 

 

 

No water or very low

The handset sprayplate is

Regularly clean the handset

flow rate.

blocked.

sprayplate. Refer to the

 

 

Maintenance section of the

 

 

handset manual.

 

The incoming water

Open the stop/isolating valve

 

supply stop valves, or the

completely.

 

appliance isolating valve,

 

 

is closed.

 

 

The hose or handset is

Clear the blockage or replace

 

blocked.

the hose or handset.

 

Insufficient water supply

Contact the local water

 

pressure.

authority.

 

The heater tank is

Replace the heater tank.

 

excessively scaled.

 

 

The pilot valve is faulty.

Replace the flow regulator

 

 

assembly.

 

The inlet filter is blocked.

Clean the inlet filter. See the

 

 

Maintenance: Cleaning the

 

 

Inlet Filter section.

 

The power is not turned

Switch on the power at the

 

on at the double pole

double pole switch.

 

switch.

 

 

The fuse is blown or the

Renew the fuse or reset the

 

MCB/RCD has been

MCB/RCD. If the fault

 

tripped, indicating a

persists, contact Customer

 

possible electrical fault;

Services. Replace the heater

 

for example, heater tank

tank.

 

element failure.

 

 

 

 

28

Page 28
Image 28
Kohler Electric Shower manual Maintenance Cleaning the, Inlet Filter section, Malfunction, Cause, Remedy