Malfunction | Cause | Remedy |
|
|
|
No water or very low | The handset sprayplate is | Regularly clean the handset |
flow rate. | blocked. | sprayplate. Refer to the |
|
| Maintenance section of the |
|
| handset manual. |
| The incoming water | Open the stop/isolating valve |
| supply stop valves, or the | completely. |
| appliance isolating valve, |
|
| is closed. |
|
| The hose or handset is | Clear the blockage or replace |
| blocked. | the hose or handset. |
| Insufficient water supply | Contact the local water |
| pressure. | authority. |
| The heater tank is | Replace the heater tank. |
| excessively scaled. |
|
| The pilot valve is faulty. | Replace the flow regulator |
|
| assembly. |
| The inlet filter is blocked. | Clean the inlet filter. See the |
|
| Maintenance: Cleaning the |
|
| Inlet Filter section. |
| The power is not turned | Switch on the power at the |
| on at the double pole | double pole switch. |
| switch. |
|
| The fuse is blown or the | Renew the fuse or reset the |
| MCB/RCD has been | MCB/RCD. If the fault |
| tripped, indicating a | persists, contact Customer |
| possible electrical fault; | Services. Replace the heater |
| for example, heater tank | tank. |
| element failure. |
|
|
|
|