Malfunction | Cause | Remedy |
|
|
|
No water or very | The handset sprayplate | Clean the handset sprayplate. |
low flow rate. | is blocked. | Refer to the Maintenance |
|
| section of the handset manual. |
| The incoming water | Open the stop/isolating valve |
| supply stop valves, or | completely. |
| the appliance isolating |
|
| valve, is closed. |
|
| The hose or handset is | Clear the blockage or replace |
| blocked. | the hose or handset. |
| The power is off at the | Switch on the power at the |
| double pole switch. | double pole switch. |
| The fuse is blown or the | Renew the fuse or reset the |
| MCB/RCD has been | MCB/RCD. If the fault persists, |
| tripped, indicating a | contact the shower installer. |
| possible electrical fault |
|
|
|
|
No hot water from | Other water outlets are | Ensure the other water outlets, |
shower, with the | being used during | such as the washing machine or |
knobs in any | showering, causing the | dishwasher, are not in use |
position. | water pressure to drop | during showering. |
| below the minimum |
|
| required. |
|
| The water pressure is | Ensure that the incoming water |
| below the minimum | supply stop and the isolating |
| required. | valve are completely open. If |
|
| the fault persists, contact the |
|
| shower installer. |
| Failure of pressure switch, | Contact installer to replace |
| micro switch or thermal | faulty parts. |
| switch. |
|
Shower | The temperature is set | Turn the temperature knob |
temperature | too high. This is causing | anticlockwise to reduce the |
cycles between | the thermal switch to | water temperature. |
hot and cold. | turn off the heating |
|
| element to reduce the |
|
| water temperature. |
|
|
|
|
26