Kohler Electric Shower manual Relief ValveAssembly - Resetting

Models: Electric Shower

1 44
Download 44 pages 33.7 Kb
Page 32
Image 32
Relief ValveAssembly - Resetting

Relief ValveAssembly - Resetting

WARNING! Isolate the electrical and water supplies before removing the cover. Mains electricity connections are exposed when the cover is removed.

1.Remove the three screws that hold the cover, remove the cover.

Note! The rubber ball is ejected to reduce the damage if the outlet is blocked or the appliance is frozen.

2.Remove the five screws that hold the switch assembly, heater tank and, flow regulator assembly.

Switch Assembly

Screws

Heater

Tank

Flow Regulator

Assembly

Ball

3.Lift out the switch assembly, heater tank and flow regulator assembly.

4.Using your finger push the ball back into the tank. Do not remove the 'O' seal.

Ball

5.Refit the components in reverse order.

6.Replace the cover. If the cover does not fit easily, rotate the knobs slightly so that they fit into the spindles. Do not force the cover.

32

Page 32
Image 32
Kohler Electric Shower manual Relief ValveAssembly - Resetting