Kohler K-3900 manual Prepare the Site, Install the Dock Power Cord, 1132336-2-D, Kohler Co

Models: K-3900

1 68
Download 68 pages 27 Kb
Page 8
Image 8
Prepare the Site

Dock

Power

Cord

Supply Stop

 

GFCI/RCD

2" (51 mm)

Protected

Receptacle

 

 

 

 

 

 

 

 

8" (203 mm)

 

6"

 

(152 mm)

4"

(102 mm)

12" (305 mm) From Finished Wall

Recommended, 11-3/4" (298 mm) Min

3" (76 mm) Max Install the Dock Power Cord When Located Behind Toilet

Manual background 1-5/8"

2-5/8" Manual background(41 mm)

(67 mm)

Ø1-1/2" (38 mm) Water Supply Hole (for through-the-floor installations only)

Ø1-1/4" (32 mm) Power Supply Hole (for through-the-foor installations only)

Floor Flange

Prepare the Site

WARNING: Risk of electric shock. Disconnect power before installation or servicing.

WARNING: Risk of electric shock. Connect only to a properly-grounded, grounding-type receptacle which is protected by a 120 V, 15 A minimum, 60 Hz Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). Do not remove the grounding pin or use a grounding adapter.

WARNING: Risk of electrical shock. For hardwire installations/through-floor electrical supply: Connect only to a properly-grounded, dedicated circuit protected by an Class A Ground-FaultCircuit-Interrupter (GFCI) or Residual Current Device (RCD).

NOTE: The electrical outlet and water supply may also be located behind the toilet. If it is located behind the toilet, the water supply stop must extend no more than 3″ (76 mm) beyond the finished wall. If located behind the toilet, the supply stop must be a model that connects at a 90° angle. The handle should be easily accessible.

NOTE: Locating the supply stop behind the toilet will make it difficult to remove the back panel. It may be necessary to remove the toilet to service items behind the back panel if the supply stop extends more than 3″ (76 mm) from the wall.

Install the Dock Power Cord

If the finished wall has not been installed, route the docking station power cord if the cord will be routed through the wall.

If the finished wall is installed, drill a 3/8″ (10 mm) hole in the wall behind the toilet location for the docking station power cord.

If the docking station cord is routed through the wall, route the power cord to the docking station location from the toilet end. Route it through a wall plate or route the cord on the wall externally.