T-9
(2) Fusing/Exit Misfeed
<Detection Timing>
<Troubleshooting Procedure>
Type Des c r i p t i on
Fuser Jam The Exit Sensor is not unblocked after the predetermined period of time
has elapsed after the Paper Take-Up Switch is turned on.
Paper left at
Fusing/Exit
Section
If all of the following conditions are met:
• The Front Door or Exit Cover is opened and then closed or the machine
is turned on.
• The Paper Take-Up Switch is turned on or the Exit Sensor is blocked.
Paper Exit
Jam
The Exit Sensor is unblocked but not during the predetermined period of
time after the Paper Take-Up Switch is turned on.
Relevant Electrical Parts
Paper Take-Up Switch (S1)
Exit Sensor (PS3)
Mechanical Control Board (PWB-A)
Step Action Ref. Page
WIRING DIAGRAM
Control Signal Location
(Electrical Parts)
1 Initial check items ☞ T-6 ––
2 S1 switch check ☞ T-2 PWB-A PJ10A-1
(ON) H-2
3 PS3 sensor check ☞ T-1 PWB-A PJ8A-3
(ON) H-2
4 Replace PWB-A. – – –