D-20
Precautions for Removal/Reinstallation of the PH Unit
•NEVER touch the window on the back of the PH Unit. A dirty window can cause image
quality problems.
6. Remove three screws.
7. Remove the PH Unit.
NOTE
•When reinstalling the PH Unit, tighten the screws
in the numerical order shown in the illustration.
4136D008AC
2
3
1
Window
4558F2C515DA