T-4 2
xxxx62 DCN
received
Received Disconnect
command (DCN) from
other side at Phase D.
Failure in
machine of TX
side
Check the status
of the
machine
of TX side
xxxx63 Too many
CRP
Received Command
Repeat (CRP) from other
side more than 3 times
after sending (PPS-) Q
Command.
Line failure Retry TX
xxxx64 Too many
PPR
Received Failure to Train
(FTT) from other side
even with the minimum
speed of 2400 bps.
Line failure Retry TX
xxxx65 RNR time
Out
Other side was not in RX
mode within 60 seconds
in Flow Control.
Failure in
remote machine
Check the status
of the remote
machine
xxxx66 RTN/PIN
Received
Received Negative
response from other side
for Q Command.
Line failure Retry TX
Comm. Error (at Phase-E)
xxxx70 Time Out
Did not receive DCN
within 6 seconds at Phase
E.
Failure in
remote machine
Line failure
Check the status
of the remote
machine
Retry TX
Code Status Description Cause Action