Operating Your SDI Video Matrix Switcher

7.2.4.1 Storing Setups

 

To store a setting, do the following:

 

1. Press the STO button.

 

The Displays show the messages:

 

Enter SETUP number

Store

use two digit # 01-99

# xy

Where xy are the OUT buttons.

 

2.Press two OUT buttons, using the OUTkeys # 1 to 9, and 10 (for 0). The OUTkeys function on a decimal-basis, and not on a positional-basis. For example, to enter the # 14, press # 1 followed by # 4 (not # 14). To enter the # 3, press # 3 followed by the TAKE button1.

The TAKE LED blinks and the Displays show the messages:

STORE this SETUP ?

Store

YES -> TAKE

# xy

3.Press the TAKE button.

The memory stores the setup and the MATRIX Display shows the message:

Setup # xy stored

Note, saving a setup to an already allocated setup #, prompts the message in the MATRIX Display:

Setup already exists

Press TAKE to overwrite

Pressing the TAKE button replaces the stored setup with the current setup. Alternatively, press a different OUT button to change the setup #.

7.2.4.2 Recalling Setups

 

To recall a setting, do the following:

 

1. Press the RCL button.

 

The Displays show the messages:

 

Enter SETUP number

RECALL

use two digit # 01-99

# xy

where xy are the OUT buttons.

 

2.Press the appropriate two OUT buttons, using the OUTkeys # 1 to 9, and 10 (for 0). The OUTkeys function on a decimal-basis, and not on a positional-

1 Alternatively, pressing # 10 followed by # 3 will also enter the # 3

26

KRAMER: SIMPLE CREATIVE TECHNOLOGY

 

Page 30
Image 30
Kramer Electronics VS-1616SDI user manual Enter Setup number, Use two digit # # xy, Store this Setup ?