Installing the SDI Video Matrix Switcher

 

Figure 5: Rear Panel Dipswitches

 

Table 4: Dipswitch Definitions

 

 

Dipswitch #

Function:

1-4

Set the MACHINE # (see Table 5 in section 6￿ .3.1)

5Enables (ON) or disables (OFF) the Follow-SYSTEMmode

6Enables (ON) or disables (OFF) the SLAVE mode in a multi-channel configuration

7Disables use of a null modem adapter1 with RS-232

OFF = RS-232 connection via a null modem adapter ON = RS-232 connection without a null modem adapter

8RS-485 termination for first and last machine = ON (RS-485 line terminates with 110￿); for others = OFF (RS-485 line is open)

6.3.1Setting the MACHINE #

To control a unit via RS-232 or RS-485, each unit has to be identified via its unique MACHINE #.

Set the MACHINE #2 on a VS-1616SDIunit according to Table 5. A valid MACHINE # is from 1 to 15.

Table 5: Machine # Dipswitch Settings

MACHINE #

 

DIPSWITCH

 

 

1

2

3

4

1

ON

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

3

ON

ON

OFF

OFF

4

OFF

OFF

ON

OFF

5

ON

OFF

ON

OFF

6

OFF

ON

ON

OFF

7

ON

ON

ON

OFF

8

OFF

OFF

OFF

ON

9

ON

OFF

OFF

ON

1 See section 6￿ .4.1

2 When using a single unit, set the unit to MACHINE # 1