Using the MENU Command Sequence

1.Press the MENU button until you reach the Identifying the MACHINE command.

The MATRIX Display shows the message:

identify MACHINE

yes -> TAKE, next -> MENU

2.Press the TAKE button.

The MATRIX Display (as Figure 16 illustrates) shows the message:

Figure 16: Machine Identification

8.11Choosing the Initial RESET

Choose to reset the machine1 to the:

￿Current status2 (reloads the current setup)

￿Factory default (resets to the pre-installed factory default state3)

To reset the machine, do the following:

1.Press the MENU button until you reach the initial RESET command. The MATRIX Display shows the message:

initial RESET

yes -> TAKE, next -> MENU

2.Press the TAKE button.

The MATRIX Display shows the message:

Outkey 1: Current status

2:Factory default

3.Press the OUT button 2, for example, to reset to the factory default. The TAKE LED blinks and the Displays show the messages:

Reset to factory default

WARNING

Press TAKE to execute

!!!!!

1 Without having to switch the power off and on 2 Sometimes called a “soft reset”

3 Each VS-1616SDI unit ships in its factory default state that is a 16x16 SDI video matrix, with all setups empty and each input connected to its corresponding output (for example, 1-to-1)