Using the MENU Command Sequence

To scroll the switcher setup (instead of showing the IN/OUT range), do the following:

1.Press the MENU button until you reach the “What to INDICATE” command.

The MATRIX Display shows the message:

what to INDICATE

yes -> TAKE, next -> MENU

2. Press the TAKE button.

The Displays show the messages:

 

Use OUTkey to configure

Current:

1: scroll SETUP 2: OUTs/INs

OUTs/INs

3.Press the OUT button 1.

The TAKE LED blinks and the Displays show the messages:

Scroll switcher setup?

Current:

Press TAKE to execute

OUTs/INs

4.Press the TAKE button.

The Displays show the messages:

display mode

Current:

changed

SETUP

8.7Choosing the COMMUNICATION Setting

Choose the response option (reply or no reply).

To choose the No Reply response option, for example, do the following:

1.Press the MENU button until you reach the COMMUNICATION setting. The MATRIX Display shows the message:

COMMUNICATION setting yes -> TAKE, next -> MENU

2.Press the TAKE button.

The MATRIX Display shows the message:

Use OUTkey to configure 1: REPLY 2: No Reply

3.Press the OUT button 2.

The TAKE LED blinks and the Displays show the messages:

Set serial port No reply

Current:

Press TAKE to execute

Reply

4.Press the TAKE button again. The Displays show the messages:

36

KRAMER: SIMPLE CREATIVE TECHNOLOGY

 

Page 40
Image 40
Kramer Electronics VS-1616SDI user manual Choosing the Communication Setting