Operating a Single Machine
To achieve the best performance:
Use only good quality connection cables1 to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables).
Avoid interference from neighboring electrical appliances that may adversely influence signal quality and position your
4Operating a Single Machine
By default, the
A 16x16 SDI video switcher
Switched during the vertical interval of the external analog reference
In particular, be sure that the dipswitches are set as shown in Figure 1 (see section 6 .3 for further details). To operate a single machine, see Table 1.
Figure 1: Default Dipswitch Setup on a Single Machine
Table 1: Quick Reference Operating Guide for a Single Machine
To perform this command: | Press: |
|
|
Connect an input with an output | OUT #; IN # |
Clear (disconnect) a specific output | OUT #; OFF |
Clear (disconnect) all outputs | ALL; OFF |
Connect all outputs to a specific input | ALL; IN # |
Store a setup | STO; OUT #; TAKE |
Recall a setup | RCL; OUT #; TAKE |
Lock front panel | MENU; TAKE |
Unlock front panel | TAKE; TAKE |
Change default setup | Press the Menu button several times until you reach the |
| appropriate Menu setup command and follow the instructions |
5Your SDI Video Matrix Switcher
Figure 2 illustrates the front and rear panels of the VS-1616SDI. Tables 1 and 2 define the front and rear panels of the VS-1616SDI, respectively.
1 Available from Kramer Electronics on our Web site at http://www.kramerelectronics.com
3