FOR YOUR SAFETY READ BEFORE OPERATING
WARNING
CAUTION
BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
This unit is equipped with a gas control knob. Use only your hand to turnthe gas controlknob. Never use tools. If knob will not turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.
G3Q2 unitsare equippedwith a SureLighFMignitionsys- tem. Do not attemptto manually lightburnerson this fur- nace. Each time the thermostatcallsfor heal the burners will automaticallylight.The ignitordoes not get hot when there is no call for heat on units with SureLighF= ignition system.
Gas Valve Operation
WARNING
1 - STOPf Read the safety informationat the beginning of this section.
2 - Set thermostat to lowest setting,
3 - Turn off all electrical power to furnace,
4- This furnace is equipped with an ignition device which automatically lights the burner, Do not try to light the burner by hand.
5 - Remove unit access panel.
6 - Turn gas valve knob to OFF position. See figure 34. 7 - Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you do not smell gas go to next step.
HONEYWELL VR8205 SERIES GAS VALVE
HIGH FIRE
ADJUSTING SCREW
(under cap)
MANIFOLD
PRESSURE
TAP
LOW FIRE
ADJUSTING SCREW
(under cap)
INLET PRESSURE
TAP
GAS VALVE SHOWN IN OFF POSITION
FIGURE 34
8 - Turn gas valve knob to ON position,
9 - Replace access panel.
10 - Turn on all electrical power to unit,
11 - Set thermostat to desired setting,
12 - If the appliance will not operate, follow the instruc- tions given in "Turning Off Gas To Unit" section and call your service technician or gas supplier.
Turning Off Gas To Unit
1 - Set thermostatto lowest setting,
2- Turn off all electrice]powerto unit if service is to be performed.
3- Remove access panel.
4- Turn gas valve knob to OFF position, Do not force.
5- Replace access panel.
NOTE - The thermostatselec_on jumper on the
Applications Using A Single, Stage Thermostat
A * Heating Sequence - Mode of Operation Jumper in
NOTE - To operate in this mode, the mode of operation jumper on the
1 - On a call for heat, thermostat contacts close sending a signal to the integrated control module. Module runs
2 - Control module energizes combustion air inducer at high speed for
3 - Control module checks pressure switches and high limit switch for closed contacts.
Page 21