Bottom Return Air Applications
If return air is to terminate through the floor under the fur- nace, a direct, airtight and sealed connection must be made to the bottom of the furnace,
1 - Cut opening in floor or platform. Using knockouts provided, cut bottom of base panel. See figure 2.
KNOCKOUT PATTERN FOR BOTTOM
RETURN AIR APPLICATION
Bottom Return Air Applications
1 - Remove blower access panel.
2- Install filter clips, provided with unit, by slipping
folded section of clip on edge of bottom opening. See figure 4.
3 - Place filter in bottom of blower compartment beneath
rear filter clip. Press down on filter sides. Filter clips flex allowing filter to snap into place.
4 - To remove filter, press clip and pull filter up and out.
,v | vd |
iV | Vd |
_ |
|
FIGURE 2
2 - Bend a flange on return air plenum and lower into floor or platform opening, See figure 3.
3 - Position unit over return air opening. Seal unit air tight with return air plenum•
BOTTOM RETURN AIR APPLICATION
G32 UNIT
RETURN AIR
PLENUM
PROPERLY
SIZED FLOOR
OPENING
FIGURE 3
NOTE - Be cerefu/ not to damage insulation. Check for
tight seal,
BOTTOM RETURN FILTER INSTALLATION
REAR FILT R CLIP
URNACE
BACK
SIDE _
FURNACEFURNACE
FIGURE 4
Side Return Air Applications
Filter racks are available from Lennox for side return air applications.See figures 5 and 6.
NOTE - The filter doormay be shipped in the rack behind the filter./fnecessa_ remove the filter, retrieve the door and continuewith the installationof the rack.
1 - Align filter rack opening with the inside edge of the side return opening. Bottom of rack should be approximately 1 inch(25 mm) from the bottom and 3 inches (76 mm) from the front of the unit.
2- Screw filter rack intoplace with the eightselfddll,self tap screws provided.See figure 5.
3 - Push filter door pins through the two holes in filter door from the inside of the
Side Return Air Applications
For installations where the return air is taken fl'oma retum
air drop, unitmay be installed with mtum air entl_ through either the left or right side of the furnace.
SIDE RETURN FILTER INSTALLATION in.(turn)
BLOWER DECK _=
For side returnair applications,cut furnace cabinetat the
dimensionsgiven on page 2. Embossedcomers are pro- vided on bothcabinet sidesfor returnair opening location.
i_ii_!'2'i:i:i_:"i:ii:i:i:;'i:!:11:71:i:7i:i:7!:;:i!:ii:ii;ii'i:ii;:"" :<"': _i:":i__::i:!Ti:i;ii, _;:7:%TiJ;:::tT;;:::7:7
|
|
| RETURN AIR | ||||
|
|
| PLENUM | SIZE | |||
RETURN | 12 in. (305) | for | X | (324 X | |||
AIR | 14 in. 13561 Filter | 597) for | 14 | In (356) | Filter | ||
OPENING | t8 In. (437) | for | x | In, | |||
| 20 in, (508) | Filter | (476 | x | 507) |
| |
|
|
| for 20 In. | 1508) Filter |
This unit is not equipped with a filteror rack. A
lation of a
See figure 4.
cAa,NETBASEI; .OM,I (34)
FIGURE 5
Page 6