PLANNING YOUR INSTALLATION
COMBUSTIBLE WALL CLEARANCES
WARNING: IT IS VERY IMPORTANT THAT YOU OB- SERVE THE MINIMUM CLEARANCES.
There are listed clearances for your stove which were deter- mined in a Laboratory test using various "classes" of stove pipe or chimney. Minimums are first established for the stove itself and increased based on how much heat is transferred by each class of pipe.
NOTE: Manufactured (mobile) home installations require the use of a Type
Manufactured (Mobile) Home Standard and Residential Reduced - Using 6” (152 mm) diameter Type
MANUFACTURED (MOBILE) HOME INSTALLATIONS MUST BE EQUIPPED WITH A RAIN CAP AND SPARK ARRESTOR.
Clearances (inches / millimeters)
A. 14 / 356 | C. 17 | / 432 | E. 16 / 406 |
B. 25 / 635 | D. 9 / | 229 | F. 8 / 203 |
Residential Standard (not approved for manufactured [mobile] homes) Using 6” (152 mm) diameter, single wall connector pipe with listed
Clearances (inches / millimeters) |
| |
A. 22 / 559 | C. 25 / 635 | E. 16 / 406 |
B. 25.5 / 648 | D. 16 / 406 | F. 15 / 381 |
Residential Note: Approved for 6” (152 mm) diameter, single wall, minimum 24 MSG black or blued steel con- nector pipe with listed
Manufactured (Mobile) Home Reduced and Residen- tial Reduced Using 6” (152 mm) diameter Type
HOME INSTALLATIONS MUST BE EQUIPPED WITH A RAIN CAP AND SPARK ARRESTOR. Alcove size: 84” (213 cm) minimum height, 56” (143 cm) minimum width, and 24” (610 mm) maximum depth.
Clearances (inches / millimeters) |
| ||
A. 11 / 280 | C. 14.5 | / 369 | E. 16 / 406 |
B. 25.5 / 648 | D. 5.5 / | 140 | F. 5.5 / 140 |
Vent Height (all installations) - The pipe should extend 12 feet above the stove top, as a minimum, to achieve a stable draft.
Corner Installation
C
45°
F
Parallel Installation
A D
B
E